Short answer: R-410A is not banned in 2026. Existing R-410A systems can be kept and repaired, and new R-410A systems built from equipment made before Jan. 1, 2025 can still be installed. New home AC made from Jan. 1, 2025 must use a refrigerant under 700 GWP, usually R-454B or R-32. In Katy, the refrigerant in your system mostly depends on when it was made: across ten Katy-area ZIP codes, 59.4% of homes were built before 2010, when R-22 was still allowed in new air conditioners. To check yours by year, use the AC refrigerant and age checker.
If you've had an AC quote in Katy this year, you've probably heard "R-410A is being phased out" or "you have to switch to R-454B." Some of that is true, some is out of date, and some was never true. Here is what the federal rules actually say as of November 2026, in plain English, with links to the EPA and Federal Register sources.
The short version
- Your existing R-410A system is legal to keep using and legal to repair.
- Since Jan. 1, 2025, new residential split-system AC equipment made or imported in the U.S. has had to use a refrigerant with a global warming potential (GWP) below 700. R-410A's GWP is 2,090, so new production moved to refrigerants like R-454B (GWP 470) and R-32 (GWP 675).
- A 2026 EPA rule lets installers keep putting in new R-410A systems built from equipment made or imported before Jan. 1, 2025, until that inventory runs out.
- The federal 25C tax credit for home energy improvements has ended for systems placed in service after Dec. 31, 2025.
Why the refrigerant is changing
R-410A is a hydrofluorocarbon (HFC). The American Innovation and Manufacturing (AIM) Act of 2020 requires the U.S. to phase down HFC production and consumption to 15 percent of historic baseline levels by 2036. Under EPA's schedule, allowances dropped to 60 percent of baseline for 2024 through 2028, and they fall to 30 percent in 2029.
The AIM Act also lets EPA restrict high-GWP HFCs in specific kinds of equipment. That's the Technology Transitions program, and it's where the home AC rules come from.
Key dates, with sources
| Date | What changed | Source |
|---|---|---|
| 2010 | New R-22 air conditioners could no longer be made; units made before 2010 can still be serviced with R-22 | EPA |
| After 2020 | Only recycled, reclaimed or previously produced R-22 can be used to service existing equipment | EPA |
| Dec. 27, 2020 | American Innovation and Manufacturing (AIM) Act enacted | EPA, AIM Act |
| Jan. 1, 2025 | 700 GWP limit for new residential and light commercial AC and heat pumps made or imported | EPA technology transitions table |
| July 27, 2026 | Rule takes effect letting pre-2025 equipment inventory continue to be installed (published May 26, 2026) | Federal Register, 91 FR 31284 |
What changed on Jan. 1, 2025
For residential and light commercial air conditioning and heat pump systems, such as central split systems and mini-splits, EPA set a GWP limit of 700 starting Jan. 1, 2025. In practice, that means AC equipment coming off production lines for the U.S. now uses lower-GWP refrigerants, most commonly R-454B or R-32.
EPA's rules focus on five "specified components": condensing units, condensers, compressors, evaporator units and evaporators. Refrigerant lines are not one of them.
The 2026 update most articles missed
The original rules allowed new R-410A systems to be installed only through Dec. 31, 2025, and only if every specified component was made or imported before 2025. Plenty of articles from 2025 still say installing R-410A became illegal on Jan. 1, 2026.
That changed. On May 26, 2026, EPA published a final rule in the Federal Register (91 FR 31284) that "allows the inventory of residential and light commercial air conditioning and heat pump equipment that was manufactured in the United States or imported into the United States before January 1, 2025, to continue to be installed". It took effect July 27, 2026. EPA's sector table now lists "no installation compliance date" for systems where all specified components were made or imported before 2025.
In the rule, EPA said it acted partly because contractors had trouble getting R-454B in service cylinders in some areas in 2025.
What did not change: equipment made or imported in 2025 or later still has to meet the 700 GWP limit. You can't build a new R-410A system out of new-production parts.
One more note: some EPA pages, including parts of its HFC FAQ, still mention the old Jan. 1, 2026 date. The Federal Register rule and EPA's updated sector table are the current word. Petitions challenging the 2026 rule are pending in federal court, and as of late October 2026 no court had stayed it. If that changes, this post will be updated.
Can I still repair my R-410A system?
Yes. EPA says homeowners "can maintain and repair their systems throughout the useful life of the equipment," and that a faulty component like a condensing unit or indoor coil can be replaced with a similar R-410A component. EPA's rules do not limit using any system you already own.
Where it gets technical: EPA treats replacing both the condensing unit and the indoor coil together as a new system, even if the refrigerant lines stay. Replacing one now and the other later counts as repairs. A new system has to follow the new-system rules above.
What this means for a Katy homeowner: if your 8-year-old R-410A system needs a capacitor, a fan motor or even a compressor, repairing it is still an option. Ask the pro to price the repair against a full replacement, using the AC repair vs. replacement guide as a starting point.
What about R-22 systems?
Many original systems in older Katy neighborhoods, such as the first villages of Cinco Ranch, predate R-410A. New R-22 air conditioners could not be manufactured after 2010, and since 2020 only recycled, reclaimed or previously produced R-22 can be used for service. EPA does not require you to replace or convert a working R-22 system.
You can't swap in an R-410A outdoor unit on an R-22 indoor coil. EPA notes the pressures are incompatible and R-410A isn't approved as an R-22 retrofit, so the whole system would need replacing, and a replaced system has to meet the new GWP limit.
Which refrigerant Katy homes likely started with, by ZIP code
The year a house was built tells you which refrigerant its original AC most likely used. Across the ten ZIP codes below (277,865 housing units), 33.6% were built before 2000, 25.8% from 2000 to 2009, 33.1% from 2010 to 2019 and 7.5% in 2020 or later. Homes built before 2010 started with R-22 or early R-410A equipment; homes built from 2010 on started with R-410A. No home in this data was built late enough to count the 2025 change, because the survey covers 2020 to 2024.
This is an estimate of original equipment, not of what is in Katy homes today. Many older systems have been replaced, often more than once, so the share of homes still running R-22 is lower than the "before 2000" column. The data plate on your outdoor unit is the only sure answer. Source: U.S. Census Bureau, American Community Survey 2020 to 2024 5-year estimates (tables B25034, B25035 and B25003, by ZIP Code Tabulation Area). Area names are approximate; ZIP codes don't follow subdivision lines.
| ZIP code | Area | Built before 2000 (original likely R-22) | Built 2000 to 2009 (R-22 or R-410A) | Built 2010 to 2019 (original R-410A) | Built 2020 to 2024 (original R-410A) | Median year built |
|---|---|---|---|---|---|---|
| 77450 | Katy (east, older Cinco Ranch sections) | 64.1% | 28.2% | 7.4% | 0.3% | 1994 (±1) |
| 77084 | West Houston (Bear Creek area) | 56.4% | 24.8% | 15.9% | 2.9% | 1996 (±2) |
| 77479 | Sugar Land | 56.4% | 20.9% | 21.1% | 1.6% | 1998 (±1) |
| 77423 | Brookshire | 43.2% | 15.9% | 26.9% | 14.0% | 2004 (±4) |
| 77449 | Katy (north) | 35.3% | 34.4% | 24.5% | 5.8% | 2004 (±1) |
| 77406 | Richmond | 28.2% | 23.1% | 40.3% | 8.4% | 2009 (±2) |
| 77494 | Katy (south and west) | 10.9% | 35.3% | 46.7% | 7.2% | 2011 (±1) |
| 77407 | Richmond (Grand Parkway side) | 6.5% | 24.7% | 58.7% | 10.0% | 2013 (±1) |
| 77493 | Katy (north and west) | 21.8% | 11.5% | 43.3% | 23.3% | 2014 (±1) |
| 77441 | Fulshear | 5.3% | 13.5% | 64.1% | 17.2% | 2015 (±1) |
The pattern is sharp. In 77450, which includes older Cinco Ranch sections, 64.1% of homes predate 2000. In Fulshear's 77441, 81.3% were built in 2010 or later. To check a specific system by year, use the refrigerant and age checker. If a repair quote involves an older system, the repair or replace calculator walks through the $5,000 rule of thumb, a decision threshold rather than a price. Katy AC Pros does not set or quote prices. More home-age detail is in Katy AC age by ZIP code.
R-454B and R-32: what's different
Both carry the A2L safety class in EPA's SNAP listings, and EPA lists them as acceptable for new home AC only subject to use conditions. EPA describes refrigerants like these as mildly flammable. EPA and industry standards prohibit using mildly flammable refrigerants like R-454B or R-32 in systems that weren't designed for them. So you can't top off an R-410A system with R-454B; the equipment has to be built for it.
What that means for you: A2L systems come with their own installation and service conditions, so ask whether the company regularly installs and services the refrigerant your quote lists.
On price: EPA's 2026 rule says pre-2025 R-410A inventory "could be a lower cost option for consumers". Quotes vary by home and by company, so compare written quotes for both options if they're offered.
Is there still a federal tax credit for a new AC?
No. The federal Energy Efficient Home Improvement Credit (Section 25C) has ended for new work. The IRS says the credit is not allowed for property placed in service after December 31, 2025. If a qualifying system was installed in 2025, a tax professional can advise on a 2025 return.
What to ask before you approve a quote
- Which refrigerant does this system use: R-410A, R-454B or R-32?
- If it's R-410A, were all the major components made or imported before 2025? (That's what makes a new R-410A install legal.)
- Am I getting a full new system, or replacing one part? (Both outdoor and indoor coil together counts as a new system.)
- What does the warranty cover, and who registers it?
- What is your TDLR air conditioning and refrigeration license number? Texas requires one for contractors who install, repair or maintain AC systems.
- Is a Manual J load calculation included? A right-sized system matters more than the refrigerant label. See AC installation in Katy.
Also confirm the efficiency rating. The federal minimum for split-system central AC installed in Texas since 2023 is 14.3 SEER2 for systems under 45,000 Btu/h and 13.8 SEER2 at or above it.
Frequently Asked Questions
Is R-410A banned in 2026?
No. Existing R-410A systems can keep running and can be repaired. New R-410A systems can still be installed if all major components were made or imported before Jan. 1, 2025. New equipment made in 2025 or later must use a refrigerant under 700 GWP.
Do I have to replace my R-410A AC?
No. EPA's rules don't require anyone to stop using an existing system.
Can a pro put R-454B in my R-410A system?
No. Mildly flammable refrigerants like R-454B can't be used in systems not designed for them.
Is R-454B more expensive?
It depends on the home and the quote. EPA noted pre-2025 R-410A inventory could be a lower-cost option. Compare written quotes.
Can I still get the 25C tax credit for a new AC?
Not for systems placed in service after Dec. 31, 2025.
My house was built in the 1990s. What refrigerant does it use?
If it's the original system, likely R-22. Check the data plate on the outdoor unit.
Get connected with a local AC pro
Not sure what your system uses? Start with the refrigerant and age checker, or call (281) 653-5399 to get connected with an independent local AC pro who serves Katy, Cinco Ranch, Cross Creek Ranch and Fulshear. For a broken system, start with AC repair in Katy. To see what this means by neighborhood, read the Katy neighborhood AC guide.